System validation and density fluctuation calibration of phase contrast imaging (PCI) on an HL-2A tokamak are presented. Signals from different channels show not only a pronounced modulation of an incident laser beam induced by a sound wave, but also an excellent magnification and low image distortion of optics. The frequency-wavenumber spectrum is achieved by using two-dimensional Fourier transform of time series signals. The conversion coefficient between detected signal amplitude and chord integral plasma density fluctuation is 2.35 × 1013 m 2/mV, which promises a suitable signal level at the order of volts of the PCI in typical HL-2A discharges.
120.5050 Phase measurement 150.1488 Calibration 350.5400 Plasmas 120.5060 Phase modulation 
Chinese Optics Letters
2018, 16(12): 121201
尹相辉 1,2,*李颖颖 2符佳 2江堤 2,3[ ... ]万宝年 2
作者单位
摘要
1 中国科学技术大学核科学技术学院, 安徽 合肥 230026
2 中国科学院等离子体物理研究所, 安徽 合肥 230031
3 安徽大学物理与材料科学学院, 安徽 合肥 230601
4 中国科学院安徽光学精密机械研究所, 安徽 合肥 230031
5 中国科学院合肥大科学中心, 安徽 合肥 230031
电荷交换复合光谱诊断(CXRS)是在核聚变装置上测量离子温度和旋转速度分布的常规诊断方式之一。通过测量等离子体中完全电离的碳离子(C6+)与高能中性氘之间发生电荷交换辐射出的碳谱线(C VI, 529.059 nm,n=8→7)的多普勒频移来计算C6+的速度,而准确测量的前提是波长的精确标定。介绍了东方超环托卡马克装置(EAST)上CXRS系统的离线波长标定和实时波长标定方法,详细分析了二者的优缺点,针对EAST等离子体及CXRS诊断现状提出了一套应用激光(波长为532.1 nm)作为波长实时标定光源的方案,同时对该方法的有效性进行了仿真分析及实验验证。结果表明使用该方案和利用常用标准灯得到的标定结果一致。
光谱学 光谱诊断 波长标定 标准灯 激光 光谱仪 
光学学报
2016, 36(6): 0630002

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!